Hutson Industries,Inc.
1000 Hutson Circle
Frisco, TX 75034
TEL:(972)335-8600
Fax:(972)377-2197

40 AMP 1/2" PRESS FIT SCR

1. GATE
2. Cathode
3. Anode (case)
SYM.
INCHES
A
1.050
B
0.380
0.355
C
0.475
0.467
D
0.305
0.265
E
0.100
0.075
F
0.505
0.501
MAXIMUM RATINGS
SYMBOL
DEVICE NUMBERS UNITS
REPETITIVE PEAK OFF-STATE VOLTAGE AND REPETITIVE PEAK REVERSE VOLTAGE GATE OPEN, AND TJ = 110° C /VDRM
50
100
200
400
600
PS040
PS140
PS240
PS440
PS640
VOLT
RMS ON-STATE CURRENT AT TC = 80º C AND CONDUCTION ANGLE OF 360º
IT(RMS)
40
AMP
PEAK SURGE (NON-REPETITIVE)
ON-STATE CURRENT, ONE-CYCLE,
AT 50HZ OR 60HZ
ITSM
400
AMP
PEAK GATE - TRIGGER CURRENT FOR 3µSEC. MAX.
IGTM
2
AMP
PEAK GATE - POWER DISSIPATION AT IGT < IGTM
PGM
20
WATT
AVERAGE GATE - POWER DISSIPATION
PG(AV)
0.5
WATT
STORAGE TEMPERATURE RANGE
TSTG
-40 to +150
°C
OPERATING TEMPERATURE RANGE, TJ
TOPER
-40 to +150
°C
PEAK OFF - STATE CURRENT GATE OPEN, TC=110°C VDRM & VRRM=MAX. RATING
IDRM & IRRM
1.0
MA MAX.
MAXIMUM ON - STATE VOLTAGE, (PEAK)
AT TC = 25° C AND IT = RATED AMPS
VTM
1.6
VOLT MAX.
DC HOLDING CURRENT, GATE
OPEN AND TC = 25° C
IHO
50
MA MAX.
CRITICAL RATE-OF-RISE OF OFF-
STATE VOLTAGE, GATE OPEN, TC = 110° C
CRITICAL dv/dt
200
V/µSEC.
DC GATE-TRIGGER CURRENT FOR ANODE
VOLTAGE = 12VDC, RL = 60 W AND AT TC = 25° C
IGT
25
MA MAX.
DC GATE - TRIGGER VOLTAGE FOR ANODE VOLTAGE = 12VDC, RL = 60 W AND AT TC = 25° C
VGT
2.0
VOLT MAX.
GATE-CONTROLLED TURN-ON TIME FOR
TD + TR, IGT = 150 MA AND TC = 25° C
T gt
2.5
µSEC.
THERMAL RESISTANCE, JUNCTION-TO-CASE
RqJ-C
0.9
°C/WATT TYP