TO-220 ISOLATED* SCR
1. Cathode
2. Anode
3. GATE
MAXIMUM RATINGS
SYMBOL
DEVICE NUMBERS
UNITS
REPETITIVE PEAK OFF-STATE VOLTAGE
REPETITIVE PEAK REVERSE VOLTAGE
GATE OPEN, AND TJ = 110° C /VDRM
50
100
200
400
600
IS08S
IS18S
IS28S
IS48S
IS68S
IS08
IS18
IS28
IS48
IS68
IS010
IS110
IS210
IS410
IS610
IS012
IS112
IS212
IS412
IS612
IS020
IS120
IS220
IS420
IS620
IS025
IS125
IS225
IS425
IS625
VOLT
RMS ON-STATE CURRENT AT TC = 80º C AND CONDUCTION ANGLE OF 180º
IT(RMS)
8.0
8.0
10.0
12.0
20.0
25.0
AMP
PEAK SURGE (NON-REPETITIVE) ON-STATE CURRENT, ONE-CYCLE, AT 50HZ OR 60HZ
ITSM
80
80
100
120
200
250
AMP
PEAK GATE - TRIGGER CURRENT
FOR 3µSEC. MAX.
IGTM
1
1
1
1
1
1
AMP
PEAK GATE-POWER DISSIPATION
AT IGT
< IGTM
PGM
16
16
16
16
16
16
WATT
AVERAGE GATE - POWER DISSIPATION
PG(AV)
0.5
0.5
0.5
0.5
0.5
0.5
WATT
STORAGE TEMPERATURE RANGE
TSTG
-40 TO +150
°C
OPERATING TEMPERATURE RANGE, TJ
TOPER
-40 TO +110
°C
PEAK OFF - STATE CURRENT GATE OPEN TC = 110° C VDRM & VRRM=MAX. RATING
IDRM & IRRM
(1)
0.1
0.5
0.5
0.5
0.5
0.5
MA
MAX.
MAXIMUM ON - STATE VOLTAGE, (PEAK)
AT TC = 25° C AND IT = RATED AMPS
VTM
2.0
2.0
1.8
1.65
1.5
1.8
VOLT
MAX.
DC HOLDING CURRENT,
GATE OPEN AND TC = 25° C
IHO
(1)
3
30
30
30
30
50
MA
MAX.
CRITICAL RATE-OF-RISE OF OFF-STATE VOLTAGE, GATE OPEN, TC = 110° C
CRITICAL
dv/dt
(1)
8
200
200
200
200
200
V/µSEC.
DC GATE - TRIGGER CURRENT FOR ANODE VOLTAGE = 12VDC, RL = 60 ohm AND AT TC = 25° C
IGT
500µA
25
25
25
25
35
MA
MAX.
DC GATE-TRIGGER VOLTAGE FOR ANODE VOLTAGE = 12VDC, RL = 60 ohm AND AT TC = 25° C
VGT
0.8
1.5
1.5
1.5
1.5
1.5
VOLT
MAX.
GATE CONTROLLED TURN-ON TIME
FOR TD + TR, IGT = 150 MA AND TC=25° C
TGT
2.5
2.5
2.5
2.5
2.5
2.5
µSEC.
THERMAL RESISTANCE, JUNCTION-TO-CASE
R0J-C
3
2.5
2.5
2.5
2.2
2.4
°C / WATT
TYP
NOTE: (1) R G-K=1K ohm. *ALL HUTSON ISOLATED TO-220 SCR DEVICES ARE UL RECOGNIZED. UL NUMBER E95589 (N)