TO-5 SENSITIVE and NON SENSITIVE GATE SCR

1. Cathode
2. Anode
3. GATE
MAXIMUM RATINGS
SYMBOL
DEVICE NUMBERS
UNITS
SENSITIVE
NON-SENSITIVE
REPETITIVE PEAK OFF-STATE VOLTAGE
REPETITIVE PEAK REVERSE VOLTAGE
GATE OPEN, AND TJ = 110° C /VDRM
50
100
200
400
600
HS04S
HS14S
HS24S
HS44S
HS64S
HS04
HS14
HS24
HS44
HS64
HS07
HS17
HS27
HS47
HS67
VOLT
RMS ON-STATE CURRENT AT
TC = 80º C AND CONDUCTION,
ANGLE OF 180º
IT(RMS)
4.0
4.0
7.0
AMP
PEAK SURGE (NON-REPETITIVE)
ON-STATE CURRENT, ONE-CYCLE,
AT 50HZ OR 60HZ
ITSM
40
40
80
AMP
PEAK GATE - TRIGGER CURRENT
FOR 3µSEC. MAX.
IGTM
1
1
1
AMP
PEAK GATE-POWER DISSIPATION
AT IGT < IGTM
PGM
20
20
20
WATT
AVERAGE GATE - POWER DISSIPATION
PG(AV)
0.2
0.2
0.5
WATT
STORAGE TEMPERATURE RANGE
TSTG
-40 to +150
OPERATING TEMPERATURE RANGE, TJ
TOPER
-40 to +110
PEAK OFF - STATE CURRENT, TC = 110° C
VDRM & VRRM = MAX. RATING
IDRM & IRRM
(1)
0.75
(1)
0.75
1.0
MA
MAX.
MAXIMUM ON - STATE VOLTAGE, (PEAK)
AT TC = 25° C AND IT = RATED AMPS
VTM
2.2
2.2
2.0
VOLT
MAX.
DC HOLDING CURRENT, GATE OPEN AND TC=25°C
IHO
(1)
5
(1)
10
50
MA
MAX.
CRITICAL RATE-OF-RISE OF OFF-STATE VOLTAGE, GATE OPEN, TC=110°C
CRITICAL
dv/dt
(1)
5
(1)
5
100
V/µSEC.
DC GATE - TRIGGER CURRENT FOR ANODE VOLTAGE=6VDC, RL=100 ohm AND AT TC = 25° C
IGT
200µA
1.0
25
MA
MAX.
DC GATE-TRIGGER VOLTAGE FOR ANODE
VOLTAGE=6VDC, RL=100 ohm AND AT TC=25°C
VGT
0.8
1.0
1.5
VOLT
MAX.
GATE CONTROLLED TURN-ON TIME
FOR TD + TR, IGT = 10 MA AND TC = 25° C
TGT
1.2
1.2
(2)
2.0
µSEC.
THERMAL RESISTANCE, JUNCTION-TO-CASE
R0J-C
5
5
2.5
°C / WATT
TYP
(1) RG-K = 1 K ohm
(2) t gt measured with IGT=100mA