MAXIMUM RATINGS
|
SYMBOL
|
DEVICE NUMBERS
|
UNITS
|
|
SENSITIVE
|
NON-SENSITIVE
|
REPETITIVE PEAK
OFF-STATE VOLTAGE REPETITIVE PEAK REVERSE VOLTAGE GATE OPEN, AND TJ = 110° C /VDRM |
50 100 200 400 600
|
HS04S HS14S HS24S HS44S HS64S
|
HS04 HS14 HS24 HS44 HS64
|
HS07 HS17 HS27 HS47 HS67
|
VOLT
|
RMS ON-STATE CURRENT
AT TC = 80º C AND CONDUCTION, ANGLE OF 180º |
IT(RMS)
|
4.0
|
4.0
|
7.0
|
AMP
|
PEAK SURGE (NON-REPETITIVE) ON-STATE CURRENT, ONE-CYCLE, AT 50HZ OR 60HZ |
ITSM
|
40
|
40
|
80
|
AMP
|
PEAK GATE - TRIGGER
CURRENT FOR 3µSEC. MAX. |
IGTM
|
1
|
1
|
1
|
AMP
|
PEAK GATE-POWER
DISSIPATION AT IGT < IGTM |
PGM
|
20
|
20
|
20
|
WATT
|
| AVERAGE GATE -
POWER DISSIPATION |
PG(AV)
|
0.2
|
0.2
|
0.5
|
WATT
|
| STORAGE TEMPERATURE
RANGE |
TSTG
|
-40 to +150
|
C°
|
| OPERATING TEMPERATURE
RANGE, TJ |
TOPER
|
-40 to +110
|
C°
|
PEAK OFF - STATE
CURRENT, TC = 110° C VDRM & VRRM = MAX. RATING |
IDRM & IRRM
|
(1) 0.75
|
(1) 0.75
|
1.0
|
MA MAX.
|
MAXIMUM ON - STATE
VOLTAGE, (PEAK) AT TC = 25° C AND IT = RATED AMPS |
VTM
|
2.2
|
2.2
|
2.0
|
VOLT MAX.
|
| DC HOLDING CURRENT,
GATE OPEN AND TC=25°C |
IHO
|
(1) 5
|
(1) 10
|
50
|
MA MAX.
|
| CRITICAL RATE-OF-RISE
OF OFF-STATE VOLTAGE, GATE OPEN, TC=110°C |
CRITICAL dv/dt
|
(1) 5
|
(1) 5
|
100
|
V/µSEC.
|
| DC GATE - TRIGGER
CURRENT FOR ANODE VOLTAGE=6VDC, RL=100 ohm AND AT TC = 25° C |
IGT
|
200µA
|
1.0
|
25
|
MA MAX.
|
DC GATE-TRIGGER
VOLTAGE FOR ANODE VOLTAGE=6VDC, RL=100 ohm AND AT TC=25°C |
VGT
|
0.8
|
1.0
|
1.5
|
VOLT MAX.
|
GATE CONTROLLED
TURN-ON TIME FOR TD + TR, IGT = 10 MA AND TC = 25° C |
TGT
|
1.2
|
1.2
|
(2) 2.0
|
µSEC.
|
| THERMAL RESISTANCE,
JUNCTION-TO-CASE |
R0J-C
|
5
|
5
|
2.5
|
°C / WATT TYP
|