TO-92 TRIAC

1. MT 1
2. GATE
3. MT 2
MAXIMUM RATINGS
SYMBOL
DEVICE NUMBERS
UNITS
REPETITIVE PEAK OFF-STATE VOLTAGE (1)GATE OPEN, AND TJ=110°C /VDRM
200
400
600
TBS
TDS
TMS
TBD
TDD
TMD
TBG
TDG
TMG
TBH
TDH
TMH
VOLT
RMS ON-STATE CURRENT AT
TC = 50º C AND CONDUCTION, ANGLE OF 360º
IT(RMS)
1.0
1.0
1.0
1.0
AMP
PEAK SURGE (NON-REPETITIVE) ON-STATE CURRENT, ONE-CYCLE, AT 50HZ OR 60HZ
ITSM
20
20
20
20
AMP
PEAK GA TE - TRIGGER CURRENT FOR 3µSEC. MAX.
IGTM
1
1
1
1
AMP
PEAK GATE-POWER DISSIPATION AT
IGT< IGTM
PGM
10
10
10
10
WATT
AVERAGE GATE - POWER DISSIPATION
PG(AV)
0.2
0.2
0.2
0.2
WATT
STORAGE TEMPERATURE RANGE
TSTG
-40 TO +150
°C
OPERATING TEMPERATURE RANGE, TJ
TOPER
-40 TO +110
°C
PEAK OFF - STATE CURRENT (1) GATE OPEN TC = 110° C VDRM = MAX. RATING
IDRM
0.1
0.1
0.1
0.1
MA
MAX.
MAXIMUM ON - STATE VOLTAGE, (1)
AT TC = 25° C AND IT = RATED AMPS
VTM
1.6
1.6
1.6
1.6
VOLT
MAX.
DC HOLDING CURRENT, (1) GATE
OPEN AND TC = 25° C
IHO
5
10
15
25
MA
MAX.
CRITICAL RATE-OF-RISE OF OFF-
STATE VOLTAGE, (1) FOR VD =
VDRM GATE OPEN, TC = 110° C
CRITICAL

dv/dt

10
10
20
25
V/µSEC.
CRITICAL RATE-OF-RISE OF
COMMUTATING VOLTAGE, (1) AT
TC = 80° C, GATE UNENERGIZED,
VD = VDRM, IT = IT (RMS)
COMMUTATING dv/dt
1
1
1
1
V/µSEC.
DC GATE - TRIGGER CURRENT FOR
VD=12VDC. RL=60 OHM AND AT TC=25°C
(T2 + GATE + T2 - GATE-) Q 1 & 3
(T2 + GATE - T2 - GATE +) Q 2 & 4
IGT

3
5
10
25
MA
MAX.
DC GATE - TRIGGER VOLTAGE FOR
VD=12VDC. RL=60 OHM AND AT TC=25°C
VGT
2.0
2.0
2.0
2.0
VOLT
MAX.
GATE CONTROLLED TURN-ON TIME
FOR VD = VDRM IGT = 80MA TR = 0.1 µSEC. IT=10A (PEAK) AND TC = 25° C
TGT
3
3
3
3
µSEC.
THERMAL RESISTANCE, JUNCTION-TO-CASE
R0J-C
45
45
45
45
°C / WATT
TYP
THERMAL RESISTANCE, JUNCTION-TO-AMBIENT
R0J-C
100
100
100
100
°C / WATT
TYP
Notes: (1) All Values Apply in either direction.